Connecting the world
with I/O Connect

Explore IoT gateway devices to enable data connectivity and
integration with sensors such as energy meters, PLCs, DCS, OPC,
flow meters, vibration sensors, etc. Additionally, explore sensor-
integrated hardware solutions for your specific use cases, and
explore APIs to connect your gateways and systems with I/O Sense.

Flexibility

Assortment of products to
pick right architecture.

Ideal Features

Devices have the right
features to cater use cases.

Reliable

All hardwares of Faclon
are trusted by industry.

Plug and Play

Connect and start
receiving data.

IoT Products

Explore the world of I/O Connect products to integrate your assets and data sources.

Modbus 2G IoT gateway

  • Variants - ST-50, ST-51
  • Digital Input - Modbus RS 485
  • Analog Inputs - 1x 4-20mA, 2x 0-24V
  • Connects Multiple Slaves
  • Communication - 2G, TCP / MQTT
  • Local Storage for Backup
  • Operating Voltage - 12V - 24V DC
  • FOTA

Modbus 4G IoT gateway

  • Variants - ST-52 L, ST-52 P, GT-10
  • Digital Input - Modbus RS 485
  • Analog Inputs - 1x 4-20mA, 2x 0-24V
  • Connects Multiple Slaves
  • Communication - 4G LTE, TCP / MQTT
  • Local Storage for Backup
  • Operating Voltage - 12V - 24V DC
  • FOTA

Modbus Ethernet IoT gateway

  • Variants - ST-54, ST-54 P
  • Digital Input - Modbus RS 485
  • Analog Inputs - 1x 4-20mA, 2x 0-24V
  • Connects Multiple Slaves
  • Communication - Ethernet , TCP / MQTT
  • Local Storage for Backup
  • Operating Voltage - 12V - 24V DC
  • FOTA

Modbus WiFi IoT Gateway

  • Variants - ST-53, ST-53 P
  • Digital Input - Modbus RS 485
  • Analog Inputs - 1x 4-20mA, 2x 0-24V
  • Connects Multiple Slaves
  • Communication - WiFi, TCP / MQTT
  • Local Storage for Backup
  • Operating Voltage - 12V - 24V DC
  • FOTA

Modbus 4G+Ethernet IoT Gateway

  • Variants - ST-52 C
  • Digital Input - Modbus RS 485, Modbus TCP/IP
  • Analog Inputs - 1x 4-20mA, 2x 0-24V, 1 Relay O/P
  • Connects Multiple Slaves
  • Communication - 4G & Ethernet, TCP / MQTT
  • Local Storage for Backup
  • Operating Voltage - 12V - 24V DC
  • FOTA

IPC Gateway

  • Variants depending on RAM and Storage requirements
  • Digital Input - Ethernet
  • Analog Inputs - 1x 4-20mA, 2x 0-24V
  • Connects Multiple Slaves
  • Communication - 4G LTE, TCP / MQTT
  • Local Storage for Backup
  • Operating Voltage - 12V - 24V DC
  • FOTA

Steam Trap Monitoring Package

  • Smart Node with surface temperature sensors
  • Wireless and Long Range LoRa based communication
  • Flame proof enclosure
  • Battery powered
  • Plug and Play Setup
  • 4G enabled LoRa Receiver to send data to I/O Sense

Ambient Monitoring Package

  • Smart Node with Ambient temperature and humidity sensor
  • Wireless and Long Range Lora based communication
  • Battery Powered
  • Plug and Play Setup
  • 4G enabled LoRa Receiver to send data to I/O Sense

Bus Bar Monitoring Package

  • Smart node to monitor surface temperature of Bus bar
  • Silicon Strap for mounting
  • Long Battery life
  • No calibration required
  • Panel mounted Receiver with local display and RS 485 output
  • Modbus IoT gateway to send data to I/O Sense

HVAC IoT Package

  • Smart Controller for Chiller Plant Manager
  • Smart Controller for AHU Automation
  • IoT gateway device to connect controller with I/O Sense
  • Smart Controller for standalone ACs
  • FOTA
  • Wired and Wireless

API Package

  • Connect with ERPs
  • Connect Third party IoT device with I/O Sense
  • Get data from I/O Sense
  • Connect with Historian
  • HTTPS, MQTT and other protocols
  • Custom APIs